17
P21/P26/P30
5. Settings and Optimum Operating Values 5.
Machine P21 P26 P30
Basic values:
Steam pressure (saturated steam)
bar
(psi)
4 – 5
(58.0 – 72.5)
4 – 5
(58.0 – 72.5)
4 - 5
(58.0 – 72.5)
Steam temperature (max. permitted)
°C
(°F)
150
(302)
150
(302)
150
(302)
Cooling water pressure
bar
(psi)
2 – 4
(29.0 – 58.0)
2 – 4
(29.0 – 58.0)
2 – 4
(29.0 – 58.0)
Low cooling water level switch
bar
(psi)
2
(29.0)
2
(29.0)
2
(29.0)
Cooling water temperature, max.
°C
(°F)
25
(77)
25
(77)
25
(77)
Compressed air
bar
(psi)
6
(87.0)
6
(87.0)
6
(87.0)
Low air pressure switch (if present)
bar
(psi)
4
(58.0)
4
(58.0)
4
(58.0)
Cage speeds:
Cleaning /drying RPM 35 35 35
Spinning RPM 400 /500 400 /500 400 /500
Reversing cycle (cleaning) sec. 10 /5 /10 10 /5 /10 10 /5 /10
Low level
l
(US gal)
52.5
(13.9)
65
(17.2)
75
(19.8)
High level
l
(US gal)
105
(27.7)
130
(34.3)
150
(39.6)
Pump pressure (max.)
bar
(psi)
2.5
(36.3)
2.5
(36.3)
2.5
(36.3)
Filter surface, economy filter
m
2
(ft
2
)
5.0
(53.8)
5.0
(53.8)
5.0
(53.8)
Filter powder (only for machines
without emission-free still rake out
system)
kg
(lb)
2.5
(5.5)
2.5
(5.5)
2.5
(5.5)
Tank I: optimum filling volume (high
level)
l
(US gal)
110
(29.0)
135
(35.6)
155
(40.9)
Detergent solution cooler:*
Detergent solution thermal sensor:
Detergent solution cooler ON
°C
(°F)
15 – 30
(59 – 86)
15 – 30
(59 – 86)
15 – 30
(59 – 86)

Table of Contents