15
P21/P26/P30
4. Technical Specifications 4.
Machine
Heating
P26
Steam
P30
Steam
Consumption for drying:
Drying time inc. reduction min. 17 19
Elec. energy for drying
Without Slimsorba
With Slimsorba
kWh
kWh
2.8
2.6
3.0
2.8
Saturated steam for drying
Without Slimsorba
With Slimsorba
kg (lb)
kg (lb)
4.5 (9.9)
4.5 (9.9)
5.0 (11.0)
5.0 (11.0)
Cooling water for drying (12 °C/53.6 °F)
Without Slimsorba
With Slimsorba
l (US gal)
l (US gal)
95 (25.1)
85 (22.4)
105 (27.7)
95 (25.1)
Consumption for distillation(1x at low level):
Elec. energy, distillation kWh - -
Saturated steam, distillation kg (lb) 14.5 (32.0) 17.0 (37.5)
Cooling water for dist. (12 °C/53.6 °F) l (US gal) 190 (50.2) 220 (58.1)
Consumption per cycle: *
Total elec. energy
Without Slimsorba
With Slimsorba
kWh
kWh
3.2
3.0
3.4
3.2
Total saturated steam
Without Slimsorba
With Slimsorba
kg (lb)
kg (lb)
19.0 (41.9)
19.0 (41.9)
22.0 (48.5)
22.0 (48.5)
Total cooling water (12 °C/53.6 °F)
Without Slimsorba
With Slimsorba
l (US gal)
l (US gal)
285 (75.2)
275 (72.6)
325 (85.8)
315 (83.2)
Compressed air (6 bar/87 psi) l (US gal) 6 (1.6) 6 (1.6)