66
P21/P26/P30
11. Maintenance 11.
Disposing of the machine
Drain the filter
Remove, clean and dry filter discs
Drain water and safety separator or process water tank.
Dispose of process water and decant solvent.
Empty tanks. You can draw off the solvent residue by tilting the
machine and attaching one end of a flexible suction tube to an external pump and
inserting the other end through the sight-glass opening.
Empty condenser.
Empty out solvent and sludge pumps.
Do not leave any solvent residue in the base of the pump.
Empty and clean the still, dispose of residues.
Pump cooling agent out of the refrigeration unit
(done by authorized customer service technician).
On machines with Slimsorba, remove carbon from the Slimsorba and
dispose of in special waste.
Close open solvent lines tightly when disassembling the machine.
You must completely remove all residues that could present a hazard to people
and the environment.
Observe safety regulations concerning the handling of solvent (see Point 2).