74
P21/P26/P30
11. Maintenance 11.
- If necessary, add neutralization agent to the still:
Put neutralization agent into the button trap.
Pump solvent from tank 2 into the cage:
+ + + ~ 10 liter
+ + +
~ 2.6 US gal
Pump solvent with neutralization agent for distillation:
+ + + Pump suctions + + +
until it is dry
- When necessary, you must also perform maintenance work on machines with an emission-free
still rake out system with the still door open (lint balls, caked-on dirt).
Sequence of the maintenance work:
Start program P45:
+ + + Display shows
8
+
The horn sounds at the end of the program and symbol 15 disappears.
Distillation maintenance runs without rinsing.
Let the still cool overnight
Now perform the maintenance work that is described under "Sequence for additional maintenance
work.”
PROG
4
5
START
0
E
PROG
5
7
START
STOP
PROG
C
HOLD
PROG
6
2
START
STOP
PROG
C
HOLD