Battery low warning.
Time available for battery replacement: about
2 min.
Relay: max. voltage 250 V, max. current 5A
with resistive load (2A with inductive load).
Type of action: 1B-U.
Heating temperature adjustment range: from 6
°C to 24 °C.
Cooling temperature adjustment range: from
20 °C to 36 °C.
Three operating modes: MANUAL, AUTOMA-
TIC, SYSTEM OFF.
Available programs: HEATING, COOLING.
Counter (from 1 to 9,999) counting system's
hours of operation.
Manual operation enabling or system switch-
off controlled by timer, in hours or days (up to
99).
Room temperature measuring interval: every
15 s.
Temperature differential: from ±0.1 °C to ±0.9
°C, settable.
Reading resolution: 0.1 °C.
Range of reading on display: from 0 °C to +40
°C.
Precision: ±0.3 °C.
Class A software.
Pollution level: 2.
Impulse voltage: 4 kV.
Max. temperature of control head: 40 °C.
Working temperature range: from 0 °C to +40
°C.
Insulation rating: IP30.
Dimensions: 132x82x33.5 mm.