Details the distinctions between Dispensette III and Organic models, including variants.
Outlines operational limits, prohibited uses, and chemical compatibility for Dispensette instruments.
Specifies recommended applications, chemical compatibility, and proper storage conditions for the instrument.
Confirms all included items in the dispenser package, as listed in the manual.
Provides step-by-step instructions for assembling the dispenser, discharge tube, and optional valve.
Describes the priming process for Dispensette models equipped with the SafetyPrime™ recirculation valve.
Details the priming procedure for Dispensette models not equipped with the SafetyPrime™ recirculation valve.
Explains how to accurately set the desired volume for dispensing on digital and analog models.
Guides users on the correct method for performing dispensing operations safely and effectively.
Covers optional recirculation valves and various discharge tube accessories for enhanced functionality.
Describes accessories like drying tubes for moisture-sensitive media and air vent caps for micro filtration.
Details accessories such as Luer-Lock discharge tubes for sterile filtration applications.
Presents the defined accuracy and coefficient of variation limits for nominal dispensing volumes.
Details the accuracy and coefficient of variation for dispensing volumes less than the nominal capacity.
Explains the procedure for gravimetric testing to verify the instrument's dispensing accuracy.
Provides instructions on how to adjust the instrument for accurate volume delivery after prolonged use.
Outlines the general procedure and conditions for cleaning the instrument to ensure proper operation.
Details the process for removing the piston and cleaning the cylinder, including digital and analog types.
Describes the methods for cleaning or replacing the filling, discharge, and recirculation valves.
Lists essential steps and checks to perform on the instrument before the first autoclaving cycle.
Details the procedure for safely autoclaving the instrument according to specified conditions.
Lists catalog numbers for various Dispensette III models based on capacity and valve configuration.
Provides catalog numbers for Dispensette Organic models, categorized by capacity and valve type.
Details available bottle adapters for different thread sizes and various discharge tube options.
Covers accessories like filling tubes, valves, sealing washers, and screw caps.
Lists spare parts including seals, drying tubes, air vent caps, mounting tools, and bottle stands.
Explains the process for returning the instrument for repair, including necessary documentation.
Describes available calibration services, including BRAND and DAkkS certified options.
Outlines warranty terms and provides guidance on the proper disposal of the instrument.
| Type | Bottle-top dispenser |
|---|---|
| Density Limit | 2.2 g/cm³ |
| Material | PTFE, borosilicate glass |
| Autoclavable | Yes (121°C, 20 minutes) |
| Viscosity Limit | 500 mPa s |
| Compatibility | Acids, bases, solvents |
| Dosing Speed | Adjustable |