PERIODIC MAINTENANCE & ADJUSTMENT
4. FUEL FILTER
Cleaning and replacement of fuel lter element:
(1) Put the fuel shut off valve to “C” (closed) position
(2) Take out the lter and remove water and dust inside
the lter.
(3) After cleaning the lter, replace it and put the fuel
shut off valve to “O” (Open) position. Remove the air.
(4) Replace the lter element.
5. COOLANT
Do not open the radiator cap while the
engine is running or right after the engine
is stopped. Open the radiator cap only af-
ter the engine is stopped and fully cooled
down.
DANGER
[Otherwise]
Hot water will splash and may cause burn in-
jury.