PERIODIC MAINTENANCE & ADJUSTMENT
4. FUEL FILTER
Cleaning and replacement of fuel lter element:
(1) Put the fuel shut off valve to “C” (closed) position
(2) Take out the lter and remove water and dust inside
the lter.
(3) After cleaning the lter, replace it and put the fuel
shut off valve to “O” (Open) position. Remove the air.
(4) Replace the lter element.
5. COOLANT
Do not open the radiator cap while the
engine is running or right after the engine
is stopped. Open the radiator cap only af-
ter the engine is stopped and fully cooled
down.
DANGER
[Otherwise]
Hot water will splash and may cause burn in-
jury.