Series 6A Installation, Operation & Maintenance
Calibration & Commissioning
6A O & M : 14
Series 6A with and without HART communications
Operation and Maintenance Manual, 09/2008, A5E00756809-03
OOvveerrvviieeww ooff ddiiaaggnnoossttiiccss vvaalluueess
N
N
o
o
.
.
A
A
b
b
b
b
r
r
e
e
v
v
i
i
a
a
t
t
i
i
o
o
n
n
M
M
e
e
a
a
n
n
i
i
n
n
g
g
V
V
a
a
l
l
u
u
e
e
s
s
t
t
h
h
a
a
t
t
c
c
a
a
n
n
b
b
e
e
d
d
i
i
s
s
p
p
l
l
a
a
y
y
e
e
d
d
U
U
n
n
i
i
t
t
R
R
e
e
s
s
e
e
t
t
p
p
o
o
s
s
s
s
i
i
b
b
l
l
e
e
1 STRKS Stroke number (Strokes) 0 ... 4.29E9 - X
2 CHDIR Changes of direction (Changes of Direction) 0 ... 4.29E9 - X
3 CNT Number of fault messages ( Counter) 0 ... 4.29E9 - X
4 A1CNT Number of alarms 1 (Alarm 1 Counter) 0 ... 4.29E9 - X
5 A2CNT Number of alarms 2 (Alarm 2 Counter) 0 ... 4.29E9 - X
6 HOURS Operating hours (Hours) 0 ... 4.29E9 Hours -
7 WAY Determined actuator travel (Way) 0 ... 130 mm or ° -
8 TUP Actuating time up (Travel Time Up) 0 ... 1000 s -
9 TDOWN Actuating time down (Travel Time Down) 0 ... 1000 s -
10 LEAK Leakage (Leakage) P 0.0 ... 100.0 % -
11 PST Monitoring of the partial stroke test OFF / ###.#, fdini,
notSt, SdtSt,
fdtSt, notd, Strt
s for ###.# -
12 PRPST Time since the last Partial-Stroke-Test ###, notSt, Sdtst,
fdtSt
Days -
13 NXPST Time until the next Partial-Stroke-Test ###, notSt, SdtSt,
fdtSt
Days -
14 DEVI General control valve fault OFF, 0.0 ... 100.0 % -
15 ONLK Pneumatic leakage OFF, 0.0 ... 100.0 - -
16 STIC Static friction/Slipstick effect OFF, 0.0 ... 100.0 % -
17 ZERO Zero point displacement OFF, 0.0 .. 100.0 % -
18 OPEN Displacement of upper end stop OFF, 0.0 ... 100.0 % -
19 PAVG Position average 0.0 ... 100.0 % -
20 P0 Potentiometer value of lower end stop (0%) 0.0 ... 100.0 % -
21 P100 Potentiometer value of upper end stop (100%) 0.0 ... 100.0 % -
22 IMPUP lmpulse length up (Impuls Length Up) 2 ... 160 ms -
23 IMPDN Impulse length down (Impuls Length Down) 2 ... 160 ms -
24 DBUP Dead zone up (Dead Band Up) 0.1 ... 10.0 % -
25 DBDN Dead zone down (Dead Band Down) 0.1 ... 10.0 % -
26 SSUP Slow step zone up (Short Step Zone Up) 0.1 ... 100.0 % -
27 SSDN Slow step zone down (Short Step Zone Down) 0.1 ... 100.0 % -
28 TEMP Current temperature -40 ... 85 °C -
29 TMIN Minimum temperature ("min/max pointer") -40 ... 85 °C -
30 TMAX Maximum temperature ("min/max pointer") -40 ... 85 °C -
31 T1 Number of operating hours in temperature range 1 0 ... 4.29E9 Hours -
32 T2 Number of operating hours in temperature range 2 0 ... 4.29E9 Hours -
33 T3 Number of operating hours in temperature range 3 0 ... 4.29E9 Hours -
34 T4 Number of operating hours in temperature range 4 0 ... 4.29E9 Hours -
35 T5 Number of operating hours in temperature range 5 0 ... 4.29E9 Hours -
36 T6 Number of operating hours in temperature range 6 0 ... 4.29E9 Hours -
Overview of Diagnostics Values

Other manuals for Bray 6A series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bray 6A series and is the answer not in the manual?

Bray 6A series Specifications

General IconGeneral
BrandBray
Model6A series
CategoryValve Positioners
LanguageEnglish

Related product manuals