EasyManuals Logo

Bray 6A series User Manual

Bray 6A series
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customer’s detailed knowledge and experience with their
application.
Series 6A Installation, Operation & Maintenance
Calibration & Commissioning
6A O & M : 15
Overview of Diagnostics Values (cont.)
Series 6A with and without HART communications
Operation and Maintenance Manual, 09/2008, A5E00756809-03
N
N
o
o
.
.
A
A
b
b
b
b
r
r
e
e
v
v
i
i
a
a
t
t
i
i
o
o
n
n
M
M
e
e
a
a
n
n
i
i
n
n
g
g
V
V
a
a
l
l
u
u
e
e
s
s
t
t
h
h
a
a
t
t
c
c
a
a
n
n
b
b
e
e
d
d
i
i
s
s
p
p
l
l
a
a
y
y
e
e
d
d
U
U
n
n
i
i
t
t
R
R
e
e
s
s
e
e
t
t
p
p
o
o
s
s
s
s
i
i
b
b
l
l
e
e
37 T7 Number of operating hours in temperature range 7 0 ... 4.29E9 Hours -
38 T8 Number of operating hours in temperature range 8 0 ... 4.29E9 Hours -
39 T9 Number of operating hours in temperature range 9 0 ... 4.29E9 Hours -
40 VENT1 Number of switching cycles of pilot valve 1 0 ... 4.29E9 - -
41 VENT2 Number of switching cycles of pilot valve 2 0 ... 4.29E9 - -
42 STORE Save the current value as "last maintenance" (press
the increment button for 5 s) (Store)
- - -
43 PRUP Prediction up 1 ... 40 - -
44 PRDN Prediction down 1 ... 40 - -
45 WT00 Number of operating hours in the actuating range
WT00
0 ... 4.29E9 Hours X
46 WT05 Number of operating hours in the actuating range
WT05
0 ... 4.29E9 Hours X
47 WT10 Number of operating hours in the actuating range
WT10
0 ... 4.29E9 Hours X
48 WT30 Number of operating hours in the actuating range
WT30
0 ... 4.29E9 Hours X
49 WT50 Number of operating hours in the actuating range
WT50
0 ... 4.29E9 Hours X
50 WT70 Number of operating hours in the actuating range
WT70
0 ... 4.29E9 Hours X
51 WT90 Number of operating hours in the actuating range
WT90
0 ... 4.29E9 Hours X
52 WT95 Number of operating hours in the actuating range
WT95
0 ... 4.29E9 Hours X
D
D
i
i
a
a
g
g
n
n
o
o
s
s
t
t
i
i
c
c
v
v
a
a
l
l
u
u
e
e
5
5
3
3
N
N
o
o
.
.
A
A
b
b
b
b
r
r
e
e
v
v
i
i
a
a
t
t
i
i
o
o
n
n
M
M
e
e
a
a
n
n
i
i
n
n
g
g
V
V
a
a
l
l
u
u
e
e
s
s
t
t
h
h
a
a
t
t
c
c
a
a
n
n
b
b
e
e
d
d
i
i
s
s
p
p
l
l
a
a
y
y
e
e
d
d
U
U
n
n
i
i
t
t
R
R
e
e
s
s
e
e
t
t
p
p
o
o
s
s
s
s
i
i
b
b
l
l
e
e
53 mA Setpoint current 0.0 to 20.0 mA --
Series 6A with and without HART communications
Operation and Maintenance Manual, 09/2008, A5E00756809-03
NNoo.. AAbbbbrreevviiaattiioonn MMeeaanniinngg VVaalluueess tthhaatt ccaann
bbee ddiissppllaayyeedd
UUnniitt RReesseett
ppoossssiibbllee
37 T7 Number of operating hours in temperature range 7 0 ... 4.29E9 Hours -
38 T8 Number of operating hours in temperature range 8 0 ... 4.29E9 Hours -
39 T9 Number of operating hours in temperature range 9 0 ... 4.29E9 Hours -
40 VENT1 Number of switching cycles of pilot valve 1 0 ... 4.29E9 - -
41 VENT2 Number of switching cycles of pilot valve 2 0 ... 4.29E9 - -
42 STORE Save the current value as "last maintenance" (press
the increment button for 5 s) (Store)
- - -
43 PRUP Prediction up 1 ... 40 - -
44 PRDN Prediction down 1 ... 40 - -
45 WT00 Number of operating hours in the actuating range
WT00
0 ... 4.29E9 Hours X
46 WT05 Number of operating hours in the actuating range
WT05
0 ... 4.29E9 Hours X
47 WT10 Number of operating hours in the actuating range
WT10
0 ... 4.29E9 Hours X
48 WT30 Number of operating hours in the actuating range
WT30
0 ... 4.29E9 Hours X
49 WT50 Number of operating hours in the actuating range
WT50
0 ... 4.29E9 Hours X
50 WT70 Number of operating hours in the actuating range
WT70
0 ... 4.29E9 Hours X
51 WT90 Number of operating hours in the actuating range
WT90
0 ... 4.29E9 Hours X
52 WT95 Number of operating hours in the actuating range
WT95
0 ... 4.29E9 Hours X
DDiiaaggnnoossttiicc vvaalluuee 5533
NNoo.. AAbbbbrreevviiaattiioonn MMeeaanniinngg VVaalluueess tthhaatt ccaann
bbee ddiissppllaayyeedd
UUnniitt RReesseett
ppoossssi
ibbllee
53 mA Setpoint current 0.0 to 20.0 mA --

Other manuals for Bray 6A series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bray 6A series and is the answer not in the manual?

Bray 6A series Specifications

General IconGeneral
BrandBray
Model6A series
CategoryValve Positioners
LanguageEnglish

Related product manuals