EasyManua.ls Logo

Brecknell PS3000 - Service Configuration Settings

Brecknell PS3000
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Configuration Settings
The scale is configured from the factory to match the specified settings for each unit, as defined by the product
specifications and sales brochure. Modification of the settings can be accomplished by altering user configuration
settings P11-P19. Caution: Configuration of the settings of your scale should be carried out by a trained service
technician to ensure proper operation and accuracy. Configuration is not covered under warranty.
Setup Controls
Config
Menu
Available
Settings
Default Definition Detailed Setting
P11 0,1,2
2
Units key
configuration
0 = KG only ; 1 = LB only ; 2 = units key active KG
and LB
P12 0-7 7 Power-on zero
range
0 = +/- 1% ; 1 = +/- 2% ; 2 = +/- 5% ; 3 = +/- 10% ; 4 =
+/- 20% ; 5 = +/- 50% ; 6 = +/- 100% ; 7 = no limitation
P13 00 - 15 03 Zero button
range
(00) = +/- 1% (06) = +/- 20% (12) = + 5%
(01 )= +/- 2% (07) = +/-no limit (13) = + 10%
(02 )= +/- 3% (08 )= + 1% (14) = + 20%
(03 )= +/- 4% (09) = + 2% (25) = + no limit
(04) =+/- 5% (10 )= + 3%
(05 )= +/- 10% (11) = + 4%
P14 0, 1, 2 0 Signal within
power on zero
point range
0 = current weight ; 1 = calibration zero ; 2 = power off
zero point
P15 0, 1, 2 1 Signal not
within power on
zero point
0 = current weight ; 1 = calibration zero ; 2 = power off
zero point ; 3 = continuously display ā€œ0
- - - - -
ā€œ
P16 0-8
6 Zero tracking 0 = 0d AZT off ; 1 = +/- 0.25d, 2 = +/- 0.5d ; 3 = +/- 1d;
4= +/- 1.5d ;5= +/- 2d ;6 = +/- 3d; 7= +/- 4d; 8 = +/- 5d
P17 0-3 3 Data Filter 0 = very weak; 1 = weak; 2 = standard; 3 = strong
P18 0 - 9 9 Weight stability 0 = +/- 0.5d ; 1= +/- 1d; 2= +/- 1.5d ; 3= +/- 2d; 4= +/-
3d ;5= +/- 4d ;6 = +/- 5d; 7= +/- 6d; 8 = +/- 7d; 9 = +/-
8d
P19 0-9 1 Overload range
Full scale
0 = 0% ; 1 = +9d ; 2 = 101% ; 3 = 102% ; 4 = 405% ;
5 = 110% ; 6 = 120% ; 7 = 150%; 8 = 200%; 9 = no
limitation
Hold
Print
kg
Moves flashin
g
di
g
it
Units
Change flashing digits
Tare
kg
Saves data and move down
to next Parameter setting
.
On/Off
Zero
Exits setu
p
mode

Related product manuals