37
TROUBLESHOOTING
Problem / Symptom Solution
Strange or no measurement of Rain Sensor 1. Check the drain hole in the rain collector.
2. Check the balance indicator.
Strange or no measurement of Thermo / Hygro
Sensor
1. Check the radiation shield.
2. Check the sensor casing.
Strange or no measurement of Wind Speed and
Direction
1. Check wind cups (Anemometer).
2. Check the wind vane.
and (Signal lost for 15 minutes)
and (Signal lost for 1 hour)
1. Relocate the console and 7-IN-1 sensor closer to each
other.
2. Make sure the console is placed away from other
electronic appliances that may interfere with the wireless
communication (TVs, computers, microwaves).
3. If problem continues, reset both console and 7-IN-1
sensor.
Temperature reading too high in the day time Make certain that the sensor array is not too close to
heat generating sources or structures, such as buildings,
pavement, walls or air conditioning units.
Some condensation beneath the UV sensor may
occur overnight
This will disappear when temperature rises up under the
sun and will not aect the performance of the unit.
SPECIFICATIONS
CONSOLE
Dimensions (W x H x D) 180 x 137 x 22 mm
Weight 424.8g (with batteries)
Main power 4 x AA batteries
Supported sensors Wireless 7-IN-1 sensor (Wind speed, Wind direction, Rain gauge, Thermo-hygro, UV, Light)
RF frequency 868Mhz (for EU or UK version)
RADIO-CONTROLLED / ATOMIC CLOCK
Synchronization Auto or disabled
Clock display HH:MM:SS / Weekday
Hour format 12hr AM / PM or 24hr
Calendar DD / MM
Weekday in 5 languages EN/ FR/ DE/ ES/ IT
RCC time signal DCF or MSF (based on the country version)
DST AUTO / OFF (only available when RCC is ON)
INDOOR BAROMETER
Barometer unit hPa, inHg and mmHg
Measuring range 540 ~ 1100hPa
Accuracy
(700 ~ 1100hPa ± 5hPa) / (540 ~ 696hPa ± 8hPa)
(20.67 ~ 32.48inHg ± 0.15inHg) / (15.95 ~ 20.55inHg ± 0.24inHg)
(525 ~ 825mmHg ± 3.8mmHg) / (405 ~ 522mmHg ± 6mmHg)
Typical at 25°C (77°F)
Resolution 1 hPa / inHg is 2 decimal place / mmHg is 1 decimal place
Weather forecast Sunny / Clear, Slightly Cloudy, Cloudy, Rainy, Rainy / Stormy and Snowy
Memory modes Historical data for last 24hrs, Max / MIN
INDOOR TEMPERATURE
Temperature unit °C or °F
Range -5°C to 50°C (14°F to 122°F)
Resolution °C / °F (1 decimal place)
Accuracy
<0°C or >40°C ± 2°C (<32°F or >104°F ± 3.6°F)
0~40°C ±1°C (32~104°F ± 1.8°F)
Memory modes Historical data for last 24hrs, Max / MIN