48
2
2
Figure 40
Testing Battery
Set the digital multimeter to DC volts position.
Test the battery while installed in the equipment.
1. Disconnect wire from spark plug and
ground ignition using Ignition Tester
#19368.
2. Attach RED meter test clip to positive (+)
battery terminal. Attach BLACK meter test
lead to negative (-) battery terminal.
3. Turn switch to START. Meter should
display 9 volts or more while cranking
engine. If less than 9 volts, replace
battery.
NOTICE: To prevent damage to the starter
motor, do not crank starter for more than 15
seconds without allowing starter to cool at least 2
minutes.