23
Water NO
Foam NO
Powder YES
CO2 YES
Warning
This table contains general instructions to be
used as guidelines for users. All the applications
of each type of extinguisher must be obtained
from the relevant manufacturer.
9.DETAILED MACHINE
OPERATION:
9.1 How to balance a tire?
1. Switch on the power source
2. Select the cone according to the tire. Assemble
the tire on the main shaft of the wheel balancer
and firmly lock it.
3. Input the tire parameter.
3.1 Pull out the scale of the balancer to measure
the Di value which means the distance from the
insider of the tire to the body. According to
measured reading, the unit of which is cm, press
,to adjust the value to make the value
displayed in the right side window to be the
measured value. But the unit of this displayed
value is mm. eg you should input 55mm if the
measured value is 5.5cm.
3.2 Use the width measurement scale to measure
the Bre。you can press to input the Br
value which is the implied value with the unit of
inch. If you want to convert this value into the
value with the unit of mm, press to
realize the conversion between the units.
3.3 Check the D value, which means the diameter
of the rim, marked on the tire. Press the key
to realize the conversion of the Br unit .
4. Lower down the protective cover(you can also
press the start key). After the machine start,
rotate and test, it will automatic stops. In the left
/right window, the corresponding values will be
displayed. Rotate the tire, when all the position
indication lamps light. Pls add the weight
corresponding to the value displayed in the
window. Once again, start the machine to test.
The window will display the unbalance value. The
balance process will be completed until reaching
the balance range you requied.
9.2 Herewith, we will not explain the ALU mode in
detail,the operation of ALU1\ALU2\ALU3\ALU4 is
according to the diagram in the chapter 6.6.
The function of the OPT mode and ALU* mode
can be seen in the demonstration CD.