Swimming Pool Heat Pump XHP
INSTALLATION
AND USER GUIDE
Illustrative photo
i
Read the instructions
EN

Questions and Answers

  • R
    rodriguezgarySep 6, 2025
    What to do if the outgoing cooling water temperature is too low in my Brilix XHP 40?
    • D
      Diane AndersonSep 6, 2025
      If the temperature of outgoing cooling water is too low in your Brilix Swimming Pool Heater, it is probably caused by insufficient water flow. Check the volume of water flow and whether or not the water passes through.
  • W
    William ChangAug 22, 2025
    What to do if my Brilix XHP 40 Swimming Pool Heater is not working?
    • M
      maxwelldylanAug 22, 2025
      If your Brilix Swimming Pool Heater isn't working, there could be a few reasons. First, check the cable connection and the circuit breaker to ensure there is a power supply. Alternatively, the heat pump may be in standby mode, in which case you should start it up. Also, the water temperature might have reached the set value, putting the heat pump in constant temperature mode; check the water temperature setting. If the heat pump has just started, wait several minutes before starting it up. Finally, defrosting might be in progress, indicated by a “defrosting” message on the LED display.
  • L
    Lisa ParsonsSep 4, 2025
    What happens during the first stage of the frost protection system of Brilix Swimming Pool Heater?
    • M
      mendozajamesSep 4, 2025
      During the first stage of the frost protection system of your Brilix Swimming Pool Heater, the pump will run automatically if the ambient temperature or the temperature of incoming water is too low.
  • J
    John McmillanSep 2, 2025
    What happens during the second stage of the frost protection system in my Brilix XHP 40?
    • D
      David MarshallSep 2, 2025
      During the second stage of the frost protection system in your Brilix Swimming Pool Heater, the heat pump will start heating automatically if the ambient temperature or the temperature of incoming water is too low.
  • J
    John TerrySep 1, 2025
    Why is there a drop in water temperature when my Brilix Swimming Pool Heater is running in heating mode?
    • R
      randallhallSep 1, 2025
      If you notice a drop in water temperature while your Brilix Swimming Pool Heater is running in heating mode, it could be due to several reasons. First, the incorrect mode might be selected, so correct the running mode. Second, the values may indicate a fault; in this case, replace the defective cable controller with the LED display, then check the condition after the change of the running mode, and check the inlet and outlet water temperature. Finally, a controller failure could be the cause, so replace the defective main controller.
  • L
    levymanuelAug 30, 2025
    What to do if my Brilix Swimming Pool Heater has a communication error?
    • H
      hugheseileenAug 30, 2025
      If your Brilix Swimming Pool Heater shows a communication error, it is likely due to a wrong connection of cables. Check the connection of cables.
  • B
    billylewisAug 29, 2025
    What to do if my Brilix XHP 40 shows an inlet and outlet temperature difference error?
    • B
      bryantravenAug 29, 2025
      If your Brilix Swimming Pool Heater displays an inlet and outlet temperature difference error, it may be caused by insufficient water flow or too low pressure difference. Check the volume of water flow and whether or not the water passes through.
  • N
    Nancy MitchellAug 27, 2025
    What to do if my Brilix Swimming Pool Heater has a short run?
    • B
      Bryan RobinsonAug 27, 2025
      If your Brilix Swimming Pool Heater experiences a short run, it could be due to the fan not running, insufficient air ventilation, or a lack of coolant. Check the cable connections between the motor and the fan, and replace them if necessary. Also, check the location of the heat pump unit and remove any obstruction preventing good air ventilation. If the problem persists, replace or repair the heat pump unit.
  • C
    Crystal BakerAug 26, 2025
    What to do if there is too much ice on the evaporator of my Brilix XHP 40?
    • T
      Tammy PerryAug 27, 2025
      If there is too much ice on the evaporator of your Brilix Swimming Pool Heater, it may be caused by insufficient air ventilation or a lack of coolant. Check the location of the heat pump unit and remove any obstructions preventing good air ventilation. If that doesn't resolve the issue, consider replacing or repairing the heat pump unit.
  • K
    Kelsey ThompsonAug 25, 2025
    Why is my Brilix XHP 40 showing protection against high pressure?
    • E
      Eric NewmanAug 26, 2025
      If your Brilix Swimming Pool Heater indicates protection against high pressure, it may be due to too much coolant or insufficient air flow. To fix this, remove the excess coolant from the heat pump system and clean the air exchanger.

Summary

Specification

Horizontal EU design, R410 A, Heating and Cooling

Details the horizontal EU design specifications for R410A, covering heating and cooling capabilities.

Performance Curves

Dimensions

Installation

Installation Illustration

Provides a visual guide illustrating the recommended installation setup for the heat pump system.

Selection of the Installation Position

Guidance on selecting an appropriate and well-ventilated location for installing the heat pump unit.

Position of Chemical Elements in the System

Highlights the importance of chemical element placement for the heater's service life, especially regarding chlorination.

Electrical Connection

Connection Diagram for XHP 40, XHP 60, XHP 100

Wiring diagram for connecting the heat pump models XHP 40, XHP 60, and XHP 100 to the power supply.

Connection Diagram for XHP 140

Wiring diagram for connecting the heat pump model XHP 140 to the power supply.

Connection Diagram for XHP 200

Wiring diagram for connecting the heat pump model XHP 200 to the power supply.

Initial Heat Pump Start-up and Winterization

Heat Pump Winterization

Essential measures to prepare the heat pump for winter to prevent damage and voiding the warranty.

Starting Up the Heat Pump After Winter

Procedure for safely starting the heat pump after the winter season, including system checks.

Setting Operating Data

Heating Only Operation

Configuration for operating the heat pump solely in heating mode.

Control Display Functions

Explains the functions of the control display, including buttons for navigation and mode selection.

Identifying Operating Parameters

Guide on how to view operating parameters and real-time data via the LED display.

Identifying the Current Mode

Instructions on how to determine the current operating mode and view various sensor readings.

Setting the Water Temperature

Procedure for adjusting the desired water temperature setting.

Setting the Locking Function

Instructions on how to lock and unlock the control panel settings to prevent accidental changes.

Setting the Clock

Guide on setting the internal clock of the heat pump control system.

Setting the Activation of the Timer

Procedure for setting the timer to activate the heat pump at a specific time.

Setting the Deactivation of the Timer

Procedure for setting the timer to deactivate the heat pump at a specific time.

Troubleshooting

Error Codes on Controller with LED Display

Lists common fault codes displayed on the controller, their causes, and recommended solutions.

Other Faults and Solutions (No Display)

Addresses operational issues and faults that occur without specific error codes displayed on the unit.

Schematic Representation and List of Parts

Spare Parts 1

Spare Parts 2

Cabling Diagram (Example - XHP 60)

Replacement of Parts

Brilix XHP 40 Specifications