EasyManua.ls Logo

Bristan Capri - Temperature Adjustment Procedure

Bristan Capri
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Adjusting the Temperature
Adjusting the TemperatureAdjusting the Temperature
Adjusting the Temperature
The shower valve has been factory set
with equal (balanced) hot and cold
water supply pressures with the hot
water supply at 65ºC.
If your operating conditions are
different from those above, the outlet
water temperature may differ from the
factory setting.
If required the shower valve can be re-
calibrated to suit your own temperature
requirements.
Set the temperature control lever to
maximum and check the temperature
of the water with a thermometer. If the
temperature is not correct, re-calibrate
the shower valve.
cap, loosen the grub screw using the
hexagonal key and carefully pull the
lever off.
3.
3. 3.
3. Using the hexagonal key, turn the
temperature adjusting screw to alter
the temperature.
Turn clockwise for a cooler
temperature
Turn anti-clockwise for a warmer
temperature
Note:
Note: Note:
Note: This will be the maximum
temperature setting, it is
recommended that the temperature is
set no higher than 43ºC.
4.
4. 4.
4. Once the correct temperature is
achieved, re-attach the lever and
close the valve. Ensure the stop on the
lever is in the correct position
Maintenance cont.
1.
1. 1.
1. Turn the lever anti-clockwise to the
maximum temperature position.
2.
2. 2.
2. Remove the lever: remove the plastic
lever is in the correct position
(vertically down), allowing the valve to
turn on anti-clockwise.
5.
5. 5.
5. Tighten the grub screw to lock the
lever in place and push fit the plastic
cap.
Temperature
adjusting screw
Cooler
Warmer
24 Need help?
Need help? Need help?
Need help? Give us a call on 0844 701 6273
0844 701 6273 0844 701 6273
0844 701 6273 and speak to one of our trained advisors.

Related product manuals