Specifications
Inlet Connections:
Inlet Connections: Inlet Connections:
Inlet Connections: 15mm compression, with adjustable centres.
Operating Pressure Range:
Operating Pressure Range: Operating Pressure Range:
Operating Pressure Range: Min: 0.1 bar – Max: 5.0 bar – Maximum recommended
imbalance between hot and cold supply should not exceed a ratio of 5:1.
Maximum Static Pressure:
Maximum Static Pressure: Maximum Static Pressure:
Maximum Static Pressure: 10.0 bar
Maximum Outlet Temperature:
Maximum Outlet Temperature: Maximum Outlet Temperature:
Maximum Outlet Temperature: Factory pre-set to 41ºC (can be re-set to suit site
conditions).
Supply Requirements:
Supply Requirements:Supply Requirements:
Supply Requirements:
Minimum cold water supply temperature: 5ºC.
Maximum cold water supply temperature: 25ºC.
Maximum hot water supply temperature: 80ºC.
(a maximum hot water supply temperature of 60 – 65ºC is recommended for ablutionary
Note:
Note: Note:
Note: The inlet hot water temperature must be at least 10ºC above the required blend
temperature (e.g. shower temperature 43ºC: minimum hot supply 53ºC.