Britony combi type 80
100
Britony combi type 80 100
BUTANE L.P.G. G30
Safety discharge
Gas rate
in bar . . . . . 3 3
Maximum in kg/h
2.04
2.45
in lb/in*. . . . . . . 43.5 43.5
Maximum in Lbs/h .
4.50
5.40 Expansion vessel
Inlet pressure
Pre-charge pressure in bar 0.7 0.7
Nominal in mbar .
28
28
Pre-charge pressure in lb/in*
9.4
9.4
Nominal in in wg .
11.2
11.2
Net capacity at 3 bar in liter
5.44 5.44
Burner pressure
Adjustable by-pass
Nominal in mbar
26,7
24
Minimum flow rate in I/h 100 100
Nominal in in wg
IO,7
9.6
Minimum flow rate in gal/min 0.36 0.36
Maximum flow rate in I/h 700 700
Burner injector diamater
Maximum flow rate in gal/min 2.56 2.56
LPG G30 and G31 in mm
0.72
0.76
Burner injector diamater
Electrical characteristics
LPG G30 and G31 in mm 0.72 0.76
Supply . 230~ 50 Hz
Consumption 150w 150w
Compartment ventilation
not required
Protection .
IP 44 IP44
Fuse+1 . . 2A 2A
Fusen”2 . .
1.25A 1.25A
External controls 24v 24v