EasyManua.ls Logo

Britony Combi 80 - Technical Data; Heat Input and Output; Gas and Pressure Specifications

Default Icon
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Britony combi type
Appliance category . . . . . . . . . .
80 100
Britony combi type 80 100
cat II 2H 3+ cat II 2H 3+
Natural gas G20
C/H circuit pressures
Min operating in bar
in lb/in2
Max operating in bar
in lb/in*
DHW flow rates
0.7 0.7
10 10
2.5 2.5
36.3 36.3
@30”CinI/min . . . . . . . . . . .
11.1
13.4
in gal/min .
2.45 2.95
@ 35°C in I/min
9.54
11.48
in gal/min
2.10 2.53
DHW circuit pressures
Min operating in bar
0.1 0.1
in lb/in2
1.45 1.45
Max operating in bar
10 10
in lb/in*
145 145
Flow limitor rate in Vmin
10 12
Gas rate
Maximum in m3/h
2.74
Maximum in ft3/h
97
Inlet pressure
3.34
118
Nominal in mbar . .
20 20
Nominal in in wg . . .
8 8
Burner pressure
Nominal in mbar .
11
12.8
Nominal in in wg . .
4.4
5.12
Burner injector diamater
Natural gas G20 in mm . 1.23 1.26
PROPANE L.P.G. G31
Gas rate
Maximum in kg/h . .
2.00
Maximum in ft3/h . .
4.41
Inlet pressure
Nominal in mbar
37
Nominal in in wg .
14.8
Burner pressure
Nominal in mbar
35
Nominal in in wg . .
14
2.42
5.34
37
14.8
30.4
12.16