• Do not place articles on or against this appliance
• Do not use or store flammable materials near this appliance
• Do not spray aerosols in the vicinity of this appliance while it is in operation
• Do not modify this appliance
1.4 Codes / Regulations
Brivis ICE units must be installed, serviced or repaired in accordance with these instructions and related
regulations, codes, standards, and authorities. These include but may not be limited to:
• Ozone Protection and Synthetic Greenhouse Gas Management Regulations 1995
• AS/ NZS 1677.2 - Australian Standard, Refrigeration systems, safety requirements for fixed
applications
• AS 4211.3 Gas recovery or combined recovery and recycling equipment
• HB 276-2004 : A Guide to Good Practice for Energy Efficient Installation of Residential Heating,
Cooling & Air Conditioning Plant & Equipment
• AS 4254 - Ductwork for air-handling systems in buildings
• AS/NZS 5141 – Residential Heating and Cooling Systems
• Local Electricity Authority
• Local Building Regulations
• Environment Authorities
• Building Code of Australia (BCA)
• Brivis “SuperSizeGuide” / Brivisize
It is recommended the Brivis “SuperSizeGuide” / Brivisize be followed in estimating cooling requirements
and for system design that will result in efficient installation and provide a higher level of comfort and
economical operation. Brivis assumes no responsibility for equipment installed in violation of any code or
regulations and these installation instructions.
Note: The communication cable installed between the Icebox coil and outdoor unit shall be:
1. Field supplied
2. 2-core shielded cable
3. Earthed at the CDU end, refer to Diagram 15.
Failure to do so may prevent the correct operation of the unit