Questions and Answers

  • M
    Margaret HuntSep 2, 2025
    What to do if my Broan B110H65RT displays error E32?
    • R
      rpadillaSep 2, 2025
      To troubleshoot an E32 error on your Broan Fan, start with a visual inspection of the exhaust damper system. Clean the filters, distribution registers, and the outside supply hood. Inspect the ducting to ensure it's not squeezed or bent. If the problem continues, remove the ducting from the supply path and check if the unit can reach the selected flow by selecting MAX on the LCD screen. If it does, examine the ducting path. If the issue persists, select the MIN and MAX flow setting values on the LCD screen, then reset the unit to display the MAX flow value. If the MAX flow is above the desired level, set the MAX and MIN flows accordingly. If the problem remains, replace the exhaust blower and repeat the flow setting steps. As a last resort, replace the electronic assembly.
  • V
    Valerie MorrisSep 14, 2025
    What to do if my Broan B110H65RT displays error E33?
    • M
      Madison PorterSep 14, 2025
      If your Broan Fan shows error code E33, try the following steps: 1. Unplug and then plug the unit back in. 2. If the problem persists, remove the core and clear the ventilation wheel of any dirt or obstructions. 3. If the error continues, disconnect J3 (red) and connect a spare blower system. If it works, replace the exhaust blower. 4. If none of these steps work, consider replacing the electronic assembly.
  • K
    Kimberly SmithAug 31, 2025
    How to troubleshoot error E41 on a Broan B110H65RT Fan?
    • A
      Andrew TateAug 31, 2025
      To resolve the E41 error on your Broan Fan, first verify that the thermistor is properly connected to connector J7B. If the error continues, disconnect connector J7B and check the resistance of the thermistor connector; it should be within 5 Kohms to 120 Kohms. If the resistance is outside of this range, replace the thermistor. If the problem persists after these steps, replace the electronic assembly.
  • J
    jackie12Sep 16, 2025
    What to do if my Broan B110H65RT Fan displays error E09?
    • C
      Christina RiceSep 16, 2025
      If your Broan Fan is showing error code E09: 1. Unplug the unit, inspect the damper system, and remove any obstructions or dirt. Note that you may need to remove filters and the core to access the damper system. Then, plug the unit back in. 2. If the problem persists, open the electrical compartment and check if connector J6 (blue) is properly inserted and inspect for any loose wires. 3. If the damper is still not moving, unplug J5 (white) from the electronic assembly and connect the blue damper system connector into J5. If the damper moves but the error persists, the electronic assembly must be replaced. Otherwise, replace the damper system.
  • M
    Mark PageSep 15, 2025
    What to do if my Broan Fan displays error E05?
    • S
      Scott GibsonSep 15, 2025
      If your Broan Fan is showing error code E05: 1. Unplug the unit, inspect the damper system, and remove any obstructions or dirt. Note that you may need to remove filters and the core to access the damper system. Then, plug the unit back in. 2. If the problem persists, open the electrical compartment and check if connector J7 (red) is properly inserted and inspect for any loose wires. 3. If the damper is still not moving, unplug J5 (white) from the electronic assembly and connect the white damper system connector into J5. If the damper moves but the error persists, the electronic assembly must be replaced. Otherwise, replace the damper system.
  • J
    janetbarronSep 23, 2025
    What to do if my Broan Fan displays error E42?
    • P
      phamseanSep 23, 2025
      If your Broan Fan displays error E42, replace the electronic assembly.
  • M
    Mark SmithAug 27, 2025
    How to fix error E01 on a Broan B110H65RT Fan?
    • M
      michaelhunterAug 27, 2025
      To troubleshoot the E01 error on your Broan Fan, follow these steps: * Unplug the unit and inspect the damper system. Remove any obstructions or dirt. You might need to remove filters and the core to access the damper system. * Plug the unit back in. If the error persists, open the electrical compartment and check if the connector J5 (white) is properly inserted and look for any loose wires. * If the damper isn't moving, unplug J7 (red) from the electronic assembly and connect the white damper system connector into J7. If the damper moves but the error remains, replace the electronic assembly. Otherwise, replace the damper system.
  • E
    Erik WilsonAug 27, 2025
    What to do if my Broan B110H65RT shows error W32?
    • M
      moralespaulaAug 27, 2025
      To fix the W32 error on your Broan Fan, start with a visual inspection of the exhaust damper system. Ensure you clean the filters, distribution registers, and the outside supply hood. Check the ducting to confirm it is not squeezed or bent. If the issue remains, remove the ducting from the supply path and select MAX on the LCD screen to check if the unit can reach the selected flow. If it can, review the ducting path. If needed, select the MIN and MAX flow setting values on the LCD screen and reset the unit. The MAX flow value will then display. If the MAX flow is above the desired level, set the MAX and MIN flows accordingly. If this doesn't resolve the issue, replace the exhaust blower and repeat setting the MIN/MAX flows. If all else fails, replace the electronic assembly.
  • A
    Amanda MitchellAug 26, 2025
    What to do if my Broan Fan displays error W22?
    • R
      Ryan CollinsAug 26, 2025
      To resolve the W22 error on your Broan Fan, start by visually inspecting the supply damper system. Clean the filters, distribution registers, and the outside supply hood. Also, check the ducting to make sure it's not squeezed or bent. If the problem continues, remove the ducting from the supply path and use the LCD screen to select MAX to see if the unit can reach the selected flow. If it can, review the ducting path. If needed, select the MIN and MAX flow setting values on the LCD screen, then reset the unit. The MAX flow value will then appear on the screen. If the MAX flow is higher than desired, set the MAX and MIN flows. If none of that helps, replace the supply blower and repeat the MIN/MAX flow settings. Finally, if nothing has worked, replace the electronic assembly.
  • D
    David CoxAug 25, 2025
    What to do if my Broan B110H65RT Fan shows error E32?
    • D
      denisepetersonAug 26, 2025
      To fix the E32 error on your Broan Fan, start with a visual inspection of the exhaust damper system. Ensure you clean the filters, distribution registers, and the outside supply hood. Check the ducting to confirm it is not squeezed or bent. If the issue remains, remove the ducting from the supply path and select MAX on the LCD screen to check if the unit can reach the selected flow. If it can, review the ducting path. If needed, select the MIN and MAX flow setting values on the LCD screen and reset the unit. The MAX flow value will then display. If the MAX flow is above the desired level, set the MAX and MIN flows accordingly. If this doesn't resolve the issue, replace the exhaust blower and repeat setting the MIN/MAX flows. If all else fails, replace the electronic assembly.