Questions and Answers

  • D
    David CoxAug 25, 2025
    What to do if my Broan B110H65RT Fan shows error E32?
    • D
      denisepetersonAug 26, 2025
      To fix the E32 error on your Broan Fan, start with a visual inspection of the exhaust damper system. Ensure you clean the filters, distribution registers, and the outside supply hood. Check the ducting to confirm it is not squeezed or bent. If the issue remains, remove the ducting from the supply path and select MAX on the LCD screen to check if the unit can reach the selected flow. If it can, review the ducting path. If needed, select the MIN and MAX flow setting values on the LCD screen and reset the unit. The MAX flow value will then display. If the MAX flow is above the desired level, set the MAX and MIN flows accordingly. If this doesn't resolve the issue, replace the exhaust blower and repeat setting the MIN/MAX flows. If all else fails, replace the electronic assembly.
  • A
    Amanda MitchellAug 26, 2025
    What to do if my Broan Fan displays error W22?
    • R
      Ryan CollinsAug 26, 2025
      To resolve the W22 error on your Broan Fan, start by visually inspecting the supply damper system. Clean the filters, distribution registers, and the outside supply hood. Also, check the ducting to make sure it's not squeezed or bent. If the problem continues, remove the ducting from the supply path and use the LCD screen to select MAX to see if the unit can reach the selected flow. If it can, review the ducting path. If needed, select the MIN and MAX flow setting values on the LCD screen, then reset the unit. The MAX flow value will then appear on the screen. If the MAX flow is higher than desired, set the MAX and MIN flows. If none of that helps, replace the supply blower and repeat the MIN/MAX flow settings. Finally, if nothing has worked, replace the electronic assembly.
  • E
    Erik WilsonAug 27, 2025
    What to do if my Broan B110H65RT shows error W32?
    • M
      moralespaulaAug 27, 2025
      To fix the W32 error on your Broan Fan, start with a visual inspection of the exhaust damper system. Ensure you clean the filters, distribution registers, and the outside supply hood. Check the ducting to confirm it is not squeezed or bent. If the issue remains, remove the ducting from the supply path and select MAX on the LCD screen to check if the unit can reach the selected flow. If it can, review the ducting path. If needed, select the MIN and MAX flow setting values on the LCD screen and reset the unit. The MAX flow value will then display. If the MAX flow is above the desired level, set the MAX and MIN flows accordingly. If this doesn't resolve the issue, replace the exhaust blower and repeat setting the MIN/MAX flows. If all else fails, replace the electronic assembly.
  • M
    Mark SmithAug 27, 2025
    How to fix error E01 on a Broan B110H65RT Fan?
    • M
      michaelhunterAug 27, 2025
      To troubleshoot the E01 error on your Broan Fan, follow these steps: * Unplug the unit and inspect the damper system. Remove any obstructions or dirt. You might need to remove filters and the core to access the damper system. * Plug the unit back in. If the error persists, open the electrical compartment and check if the connector J5 (white) is properly inserted and look for any loose wires. * If the damper isn't moving, unplug J7 (red) from the electronic assembly and connect the white damper system connector into J7. If the damper moves but the error remains, replace the electronic assembly. Otherwise, replace the damper system.
  • S
    Sarah BlairAug 28, 2025
    How to fix error E05 on a Broan Fan?
    • B
      brownluisAug 28, 2025
      To troubleshoot error E05 on your Broan Fan, follow these steps: * Unplug the unit and inspect the damper system, removing any obstructions or dirt. You may need to remove filters and the core to access the damper system. * Plug the unit back in. If the error continues, open the electrical compartment and check if connector J7 (red) is properly inserted and inspect for loose wires. * If the damper isn't moving, unplug J5 (white) from the electronic assembly and connect the white damper system connector into J5. If the damper moves but the system still shows the error, replace the electronic assembly. Otherwise, replace the damper system.
  • K
    Kristin JohnsonAug 29, 2025
    What to do if my Broan B110H65RT Fan is showing error E34?
    • L
      Lori AllisonAug 29, 2025
      If your Broan Fan displays error E34, first unplug the unit and then plug it back in. This is because the system might have detected under or over voltage due to power supply fluctuations, which stops the motor for protection. If the problem continues, replace the electronic assembly.
  • C
    cory42Aug 30, 2025
    How to troubleshoot error E40 on a Broan B110H65RT Fan?
    • P
      pturnerAug 30, 2025
      To address the E40 error on your Broan Fan, first check if the thermistor is securely connected to connector J7A. If the error persists, disconnect connector J7A and measure the resistance of the thermistor connector; it should be between 5 Kohms and 120 Kohms. If it's outside this range, replace the thermistor. If the problem still occurs, replace the electronic assembly.
  • L
    Lee LevineAug 23, 2025
    What to do if my Broan Fan shows error E50?
    • L
      luiswelchAug 23, 2025
      To address the E50 error on your Broan Fan, begin by unplugging the unit, inspecting the wires, and then plugging it back in. If the problem persists, remove the wall control from the wall and test it with a short cable. If it then works, install a new cable in the wall. If still not working, test the air exchanger with a spare wall control; if it works, replace the original wall control. As a last resort, replace the electronic assembly.
  • M
    michael91Sep 1, 2025
    How do I fix error E42 on my Broan B110H65RT?
    • M
      Molly MolinaSep 1, 2025
      To fix error E42 on your Broan Fan, replace the electronic assembly.
  • M
    Margaret HuntSep 2, 2025
    What to do if my Broan B110H65RT displays error E32?
    • R
      rpadillaSep 2, 2025
      To troubleshoot an E32 error on your Broan Fan, start with a visual inspection of the exhaust damper system. Clean the filters, distribution registers, and the outside supply hood. Inspect the ducting to ensure it's not squeezed or bent. If the problem continues, remove the ducting from the supply path and check if the unit can reach the selected flow by selecting MAX on the LCD screen. If it does, examine the ducting path. If the issue persists, select the MIN and MAX flow setting values on the LCD screen, then reset the unit to display the MAX flow value. If the MAX flow is above the desired level, set the MAX and MIN flows accordingly. If the problem remains, replace the exhaust blower and repeat the flow setting steps. As a last resort, replace the electronic assembly.