Page 14/58IOM BiRotor Plus R27
The model type is identified by the model code. Eg. B27X:
B, SB, LB – symbolizes that it is a model of BiRotor Plus series.
25 through 38 – indicates meter size in inches.
X - represents maximum working pressure of:
1 for 16 bar (DIN) / 285 p.s.i. (ANSI), OR
2 for 40 bar (DIN) / 740 p.s.i. (ANSI), OR
5 for 100 bar (DIN) / 1480 p.s.i. (ANSI), OR
6 for 200 p.s.i (Victaulic) for B27, B28, or B29 only.
The BiRotor Plus meter can be supplied with the
following approvals and certifications:
CSA 2142875
Class I, Division 1, Groups C & D T6
-40 °C < Ta < 60 °C
Class I, Division 1, Groups C & D T4
-40 °C < Ta < 60 °C
IECEx ITS 08.0021X
Ex db IIB T6 Gb IP65
-40 °C < Ta < +60 °C
Ex db IIB T4 Gb IP65
-40 °C < Ta < +60 °C
Tested to standards:
IEC 60079-0:2017
IEC 60079-1:2014
ITS 08 ATEX 15842X
ITS 22 UKEX 0503X
II 2 G Ex db IIB T6 Gb IP65
-40°C < Ta < +60°C
II 2 G Ex db IIB T4 Gb IP65
-40°C < Ta < +60°C
Tested to standards:
EN IEC 60079-0:2018
EN 60079-1:2014
Specific Conditions of Use / Schedule Limitations
/ Special Conditions for Safe Use / Special
Considerations of Certification:
• On assembly the gap between the lid and the
enclosure must be less than 0.0381mm (0.0015”)
in accordance with drawing ENG-7617-300.
• The Flameproof Joints are not intended to be
repaired or changed without the manufacturer’s
consent.
• The SB25X enclosure is to be routine pressure
tested at 170.1 psi / 11.73 bar.
General Note:
Temperature class is based on process
temperature range.
T6: 75°C Maximum Standard Process
Temperature
T4: 110°C Maximum High Process
Temperature