10. DIP SWITCH
BAS-341F, 342F
42
DIP switch A
SW No. When ON
A-5
After sewing is completed, work clamp does not automatically rise (only in split mode)
A-6
Clamping force output is produced (Inner clamping device available as an option)
A-7
Single-pedal operation using the starting switch; when the starting switch is pressed, the work clamp
drops, and when it is released, sewing starts.
A-8
Thread breakage detector device is activated
DIP switch B
SW No. When ON
B-1
Single split mode activated
B-2
Feed movement when not using work clamp, activated
B-3
Thread is not trimmed after an emergency stop.
B-4
Needle cooler output is produced.
B-5
When a rotating-type thread breakage detector device is used, detection precision is increased from 8 to 14.
When a fiber-type thread breakage detector device is used, detection precision is increased from 5 to 10.
B-6 Fiber-type thread breakage detector device is ON, and DIP switch A - 8 is ON (available as an option)
B-7
When using a 3-stage pedal
If DIP switch A -2 is ON at the same time, the presser foot will drop at the same time that work clamp drop.
B-8
Feeding speed is switched to high speed.

Table of Contents