DIP switch A
SW No. When ON
A-1
After sewing is complete, the work clamp is raised by the operator and does not rise automatically.
Various setting combinations for DIP switch No. 2, No. 3 and No. 4 can be used to change the way the work clamp is
raised and lowered.
The operation mode can be changed using the two-stage work clamp switch. (Special order)
SW
A-2
SW
A-3
SW
A-4
Type Function of work clamp pedal
- - - Pneumatic Work clamp and presser foot rise and lower simultaneously.
ON - - Pneumatic
Only work clamp rises and lowers; presser foot lowers when starting
switch is pressed.
- ON - Pneumatic For split-type presser foot, the left/right order changes alternately.
ON ON - Pneumatic
Only work clamp rises and lowers; presser foot lowers when starting
switch is pressed.
- - ON Pneumatic Work clamp and presser foot rise and lower simultaneously.
ON - ON Pneumatic
Lowers in the order right work clamp, left work clamp, presser foot;
reverse order when rising.
- ON ON Pneumatic
Lowers in the order left work clamp, right work clamp, presser foot;
reverse order when rising.
ON ON ON Pneumatic
Lowers in the order left and right work clamp, presser foot; reverse order
when rising.