2-49
Confidential
Error Code BD
Black level value abnormal during scanning.
Error Code DF
Modem communication failed.
Error Code E0
Modem does not start normally even after resetting the modem.
Error Code E2
Wired LAN MAC address not registered.
Unable to Scan BD
LCD
Step Cause Solution
1 Black level data failure Acquire white level data.
(Refer to Chapter 5, Section 1.3.17)
2 CIS unit defective Replace the CIS unit.
3 Main PCB defective Replace the main PCB ASSY.
Unable to print DF
LCD
Unable to print E0
LCD
Step Cause Solution
1
MJ PCB harness connection
failure
Reconnect the MJ PCB harness.
2 MJ PCB defective Replace the MJ PCB ASSY.
3 Main PCB defective Replace the main PCB ASSY.
Unable to Scan E2
LCD
Step Cause Solution
1 Main PCB defective Replace the main PCB ASSY.