18 [EN]
The unit then automatically stops operating.
Empty the tanks and make sure that they are correctly inserted in the machine. After a short delay, the unit will resume
operation.
If one of the tanks is removed during operation, a beep is heard and the unit stops operating.
If the red “FULL” LED flashes, the unit is in drain mode.
6) Display
The display shows the current ACTUAL humidity as standard.
If the desired SET humidity is changed, the display shows the set SET humidity.
If there is an interruption in the transmission of the radio humidity transmitter (optional accessory) to the unit, the code
05” is displayed.
If the unit was disconnected from the mains, the software version is displayed the first time the unit is switched on.
After a short time, the display automatically switches back to showing the ACTUAL humidity.
7) Further setting options
- Operation with the radio humidity transmitter (optional accessory)
Optionally the unit can be equipped with a radio humidity transmitter.
The radio humidity transmitter must be coupled to the unit. See item “Special menu”.
If the connection between the dehumidifier and the radio humidity transmitter is disturbed (e.g. no radio reception
for 10 minutes), the display shows “05”. Please note that each time the unit is switched on, the connection must first
be established and “05” is also shown in the display until the first valid radio signal is received.
- Key lock
To prevent accidental settings and to protect the unit from unauthorised access, the unit has a key lock.
To activate the key lock, press and hold the + % RHand - % RHkeys simultaneously for 6 seconds. The display
shows “88” during activation and for 3 seconds after activation.
To release the key lock, repeat the procedure and press the + % RHand - % RHkeys simultaneously for 6
seconds.
If you press a key when the keylock is active, the display shows “88”.
- Special menu
In this menu, you can make special settings such as the coding of the radio humidity transmitter, the deactivation of
the tanks for direct drainage or the condensate pump.
To activate this menu, please proceed as follows. Switch the machine off with the on/off key (1).
Now press the on/off key and hold it down for 5 seconds. The display shows Ad.
You can now switch to other sub-menus by pressing the “Setkey. You can change the settings in the menus with the
plus/minus key.