EasyManua.ls Logo

Bryant 583B - ARI Capacities (continued); Heating Capacities and Efficiencies

Bryant 583B
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
—4—
ARI* CAPACITIES (cont)
HEATING CAPACITIES AND EFFICIENCIES
LEGEND
AFUE
Annual Fuel Utilization Efficiency
NOTE:
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
UNIT 583B
HEATING INPUT
(Btuh)
OUTPUT CAPACITY
(Btuh)
TEMPERATURE RISE
RANGE (°F)
AFUE
024040
030040
40,000 31,000 20-50 80.1
024060
030060
036060
042060
60,000
46,000
46,000
46,000
47,000
35-65
35-65
25-55
20-50
78.4
78.4
78.7
78.7
036090
042090
048090
060090
88,000
90,000
90,000
90,000
70,000
71,000
70,000
70,000
45-75
35-65
25-55
25-55
79.9
79.9
78.6
78.6
048115
060115
115,000 92,000 35-65 81.1
048130
060130
130,000
104,000
103,000
40-70 80.3
M
A
N
U
F
A
C
T
U
R
E
R
C
E
R
T
I
F
I
E
D
T
O
A
R
I
A
S
C
O
M
P
L
Y
I
N
G
W
I
T
H
A
R
I
S
T
A
N
D
A
R
D
2
1
0
U
N
I
T
A
R
Y
A
I
R
C
O
N
D
I
T
I
O
N
I
N
G
E
Q
U
I
P
M
E
N
T
3
2
5
A
2

Related product manuals