3
Key features
Single cooling stage models are available from 3-5 tons.
SEERs up to 14.1.
EERs up to 12.0.
Up to 28% lighter than similar industry units. Lighter rooftop units make for easier replacement jobs.
Utility connections are the same because 3-5 ton units fit on existing Bryant rooftop curbs. This saves time and money on replace-
ment jobs.
Standardized components and layout. Standardized components and controls make service and stocking parts easier.
Scroll compressors on all units. This makes service, stocking parts, replacement, and troubleshooting easier.
Field-convertible airflow. Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site com-
plications.
Standard Direct Drive - ECM indoor motor with optional belt drive system to meet nearly all applications.
Provisions for bottom or side condensate drain.
Capable of thru-the-base or thru-the-curb gas line routing.
Single-point gas/electrical connection.
Sloped, composite drain pan sheds water and won’t rust.
Standardized controls and control box layout. Standardized components and controls make stocking parts and service easier.
Tool-less filter access door.
Clean, large, easy to use control box.
Color-coded wiring.
Large, laminated wiring and power wiring drawings are affixed to unit, making troubleshooting easy.
Single, central terminal board for test and wiring connections.
Fast-access, handled, panels for easy access on normally accessed service panels.
“No-strip” screw system guides screws into the panel and captures them tightly without stripping the screw, the panel, or the unit.
Mechanical cooling (115°F to 40°F or 46°C to 4°C) standard on all models. Winter Start Kit allows cooling operation down to
25°F (–4°C) and Motormaster
®
to –20°F (–29°C).
High efficiency gas heat with induced-draft flue exhaust design.
Induced draft motor ensures no flue gas can escape into the indoor air stream.
Bryant-designed naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be periodically, man-
ually drained. This saves labor and maintenance expense.
2-in. (51mm) disposable filters on all units.
Refrigerant filter-drier on each circuit.
Each circuit is protected with a high pressure and low pressure switch.
Many factory-installed options ranging from air management economizers, 2 position dampers, plus convenience outlets, discon-
nect switches and smoke detectors.
Standard (parts only) Warranty: 15 yr. Stainless steel, 10 yr. aluminized heat exchanger, 5 yr. compressor, 1 yr. parts.
Factory-installed Perfect Humidity
dehumidification system on all sizes with round tube/plate fin condenser coils, includes
Motormaster
®
I controller.
FEATURES/BENEFITS