Form No. PDS 598B.24.4
TWO-SPEED PURON® PLUS™
ELECTRIC AIR CONDITIONER
598B (60 HZ)
Sizes 024, 036, 048, and 060
T
W
O
-
S
P
E
E
D
Model 598B Air Conditioners incorporate innovative 2-speed
compressor technology with Puron®, the refrigerant of the
future, to provide quiet, efcient cooling performance. Built into
these units are features most desired by consumers today.
SEER ratings of up to 16.5 can be reached when combined with
specic Bryant equipment. All models are listed with UL, c-UL,
ARI, CEC, and CSA-EEV. The 598B meets the Energy Star
®
guidelines for energy efciency.
FEATURES
COIL PROTECTION
The DuraGuard coil protector, made of a
12 gage coated steel wire grid with vertical 3/8 in. spacing, is
designed to help protect the coil from inclement weather, vandal-
ism, and incidental hits. It provides protection while not restrict-
ing airow and maintaining ease of coil inspection and cleaning.
ELECTRICAL
All units are offered in 208/230v single phase.
Simplied eld-stripped lead wire connections facilitate ease of
installation.
RANGE OF SIZES
Available in 4 nominal sizes: 024, 036, 048,
and 060 to meet the needs of residential applications.
WEATHER-PROTECTED CABINET
Steel is galvanized and
coated with a layer of zinc phosphate. A modied polyester pow-
der coating is then applied and baked on, providing each unit
with a hard, smooth nish that will last for many years.
All screws on the cabinet exterior are ceramic coated for a long-
lasting, rust-resistant, high-quality appearance.
RELIABILITY BY DESIGN
The coil incorporates copper tub-
ing and enhanced, aluminum ns for optimum heat transfer. Hot
condenser air and sound are discharged vertically and away
from adjacent patio areas and foliage through the AeroMax
opening. A heat pump style basepan is used for easy removal of
water, dirt, and debris.
Auto-reset high- and low-pressure switches continuously moni-
tor system operation.
A compressor crankcase heater, energized at the proper tem-
perature during the compressor off cycle, helps to provide reli-
able starting.
TOTALLY ENCLOSED FAN MOTOR
Means greater reliability
under adverse weather conditions and dependable performance
for many years. The permanent-split-capacitor type motor was
designed for optimum efciency. The motor was tested and qual-
ied under extreme conditions to ensure the greatest reliability.
AEROQUIET FAN SYSTEM
Allows air to move through the unit
more easily which lowers sound levels and improves efciency.
APPLICATION VERSATILITY
This unit can be combined with
a wide variety of evaporator coils and fan coils to provide quiet,
dependable comfort. Unit can be installed on a roof or at ground
level on a slab.
EXTERNAL SERVICE VALVES
Both service valves are brass,
back seating type with sweat connections. Valves are externally
located so refrigerant connections can be made quickly and eas-
ily. Each valve has a service port for ease of checking operating
refrigerant pressures.
EASY SERVICEABILITY
Removal of access panel and con-
trol box cover provides easy access to the compressor and all
electrical controls. Removal of top provides access to fan motor
and coil. A self-diagnostic indicator on the electronic control
board informs the service technician of the failed component.
COMPRESSOR PROTECTION
Each compressor speed is pro-
tected with internal overloads. An internal pressure relief valve
provides high-pressure protection to the refrigerant system.
STANDARD FEATURES
An electronic control eliminates
excessive wiring. A compressor sound hood and discharge muf-
er provide improved sound levels as well as sound quality.
COMPRESSOR START ASSIST
Capacitor and relay.
EXPANSION VALVE
This unit must be installed with a Puron®
TXV on the indoor coil. The FV4 indoor fancoils and the CK5APX
furnace coils come factory equipped with a bi-ow balance port
Puron TXV. When installed in this application, no further change
is required. If any other indoor fancoil or furnace coil is used, an
accessory bi-ow, balance port TXV must be installed. See
accessory list in this publication for correct part number.
LIMITED WARRANTY
Five-year limited warranty on all parts
with a 10-year limited warranty on the compressor. Refer to war-
ranty certicate for specic details.
Question and Answer IconNeed help?

Do you have a question about the Bryant PURON PLUS 598B and is the answer not in the manual?

Bryant PURON PLUS 598B Specifications

General IconGeneral
BrandBryant
ModelPURON PLUS 598B
CategoryAir Conditioner
LanguageEnglish

Summary

Features

Coil Protection

Protects the coil from weather, vandalism, and incidental hits while allowing airflow.

Electrical

Units offered in 208/230v single phase with simplified field-stripped lead wire connections.

Range of Sizes

Available in 4 nominal sizes (024, 036, 048, 060) to meet residential needs.

Weather-Protected Cabinet

Galvanized steel cabinet with zinc phosphate and polyester powder coating for durability.

Reliability by Design

Totally Enclosed Fan Motor

Enhances reliability in adverse weather and ensures dependable performance for many years.

Easy Serviceability

Features accessible panels and a self-diagnostic indicator for efficient service.

Compressor Protection

Internal overloads and pressure relief valve protect the compressor and refrigerant system.

Limited Warranty

Five-year limited warranty on all parts, with a 10-year limited warranty on the compressor.

Dimensions

Sound Power (dBA)

Provides octave band center frequency sound power levels for various unit sizes.

Charging Subcooling* (TXV Type Expansion Device)

Recommended Tube Diameters

Specifies liquid and vapor tube diameters based on length for optimal performance.

Specifications

Electrical Specifications

Details unit voltage, ampacity, wire sizing, and fuse/breaker requirements.

Compressor and Refrigerant

Information on compressor type, refrigerant, and metering device.

Condenser Coil and Fan

Specifications for coil face area, fins, motor, airflow, and voltage.

Optional Equipment

Lists and describes optional accessories like filters and thermostats.

Combination Ratings

Detailed Cooling Capacities

598B024-A Outdoor Section with FV4ANF003 Indoor Section - High Speed

Cooling capacities for 024-A unit with FV4ANF003 indoor section at high speed.

598B024-A Outdoor Section with FV4ANB003 Indoor Section - Low Speed

Cooling capacities for 024-A unit with FV4ANB003 indoor section at low speed.

598B048-A Outdoor Section with FV4ANB006 Indoor Section - High Speed

Cooling capacities for 048-A unit with FV4ANB006 indoor section at high speed.

598B036-A Outdoor Section with FV4ANB006 Indoor Section - High Speed

Cooling capacities for 036-A unit with FV4ANB006 indoor section at high speed.

598B036-A Outdoor Section with FV4ANB006 Indoor Section - Low Speed

Cooling capacities for 036-A unit with FV4ANB006 indoor section at low speed.

598B048-A Outdoor Section with FV4ANB006 Indoor Section - High Speed

Cooling capacities for 048-A unit with FV4ANB006 indoor section at high speed.

598B048-A Outdoor Section with FV4ANB006 Indoor Section - Low Speed

Cooling capacities for 048-A unit with FV4ANB006 indoor section at low speed.

598B060-A, B Outdoor Section with FV4ANB006 Indoor Section - High Speed

Cooling capacities for 060-A/B units with FV4ANB006 indoor section at high speed.

598B060-A, B Outdoor Section with FV4ANB006 Indoor Section - Low Speed

Cooling capacities for 060-A/B units with FV4ANB006 indoor section at low speed.

Matched System

System Design

Guidelines for unit installation, operating temperatures, and refrigerant line considerations.

General

System Description

Overview of outdoor-mounted, air-cooled, split-system AC unit.

Quality Assurance

Unit rated per ARI Standard 210 and compliant with ANSI/ASHRAE, UL standards.

Delivery, Storage, and Handling

Guidelines for unit shipping, storage, and handling per manufacturer recommendations.

Warranty

Specifies warranty coverage for U.S. and Canada markets.

Products

Equipment

Factory-assembled unit containing compressor, coil, refrigerant, and controls.

Refrigerant

Puron HFC refrigerant with zero ozone depletion potential, EPA SNAP approved.

Unit Cabinet

Galvanized steel, bonderized, powder-coated paint cabinet.

Fans

Direct-drive propeller type condenser fan, discharging air upward.

Compressor

Hermetically sealed compressor mounted on rubber vibration isolators.

Condenser Coil

Air-cooled coil constructed of aluminum fins mechanically bonded to copper tubes.

Refrigeration Components

Includes shutoff valves, Puron charge, TXV, and high/low pressure switches.

Operating Characteristics

Details unit capacity, suction temp, power consumption, and SEER ratings.

Electrical Requirements

Nominal voltage, frequency, and single-point connection details.

Special Features

Refers to accessories and available enhancements for specific unit features.