If at the end of the day, the filtering pump operates for less time than
stipulated by the equipment for an optimum level of chlorine in the
water, the equipment will display a warning message.
4.1.4.5 Location of the swimming pool
Attention: This work mode only affects the semi-
automatic operation mode.
The swimming pool may be installed outdoors or indoors. Function
changes between INDOOR and OUTDOOR when the OK key is pressed.
With this function, the equipment automatically reduces production to ½
if it is an indoor pool to avoid excess chlorine.
4.1.4.6- Cover
The equipment may detect the presence of a cover on the swimming
pool (only for automatic covers). In this case, it is only necessary to
place the limit switch of the cover in the terminal block, as indicated in
the section on electrical installation.
On placing the cover, the chlorinator automatically reduces production to
20%. This variation will be reflected in the production %, and the letter
"C" will be displayed on the right side of production in the main screen.
This will indicate that the cover is activated.
Once the cover detect ion is activated, the system will ask which is the
type of sensor you have installed: Normally open (N.O.) or Normally
Closed (N.C.)