4.1.5.1- Production of cl.
Configuration of the maximum production of chlorine.
From 0% to 100% Press “OK” and use the arrows to change the
value. Press "OK" to confirm the adjustment.
Note: Chlorine production may be limited regardless of the operation
mode (manual, automatic...) that is selected.
4.2.5.2- Adjustment of the set value (Max. ORP or Max. PPM)
ORP Mode in which a Redox probe (OPTIONAL) is installed.
In this case, adjust the oxidation potential to the required level. For
private swimming pools that are not used frequently, 650 mV is a
sufficient value 700 mV is the suitable value for the majority of
swimming pools. Press "OK" to confirm the adjustment. However, the
best way to adjust the optimal ORP value is to analyze the water and
determine the ratio between ORP and PPM, because there are some
differences between several types of water.
NOTE: if working in automatic, you can also adjust the production
percentage from 0% to 100%,
PPM Mode in which a free chlorine probe (OPTIONAL) is installed.
In this case, adjust the value in ppm as required. A value between 1ppm
and 1.5ppm is correct.
NOTE: if working in automatic, you can also adjust the production
percentage from 0% to 100%,
On connecting the equipment in automatic mode, the ORP/PPM value will
flash for 5 min before the equipment starts to produce chlorine.
4.1.5.3- Super chlorination
Select this option if you require super-chlorination of your swimming
pool, bearing in mind the following: