1.3.2 Common features in all EVO equipment
- Adjustment of chlorine production by switched mode power supply
- Power supply performance >90%
- Automatic switch-off owing to lack of water flow
- Automatic switch-off owing to the accumulation of gas in the cell, with
automatic restart once the water flow is restored.
- Automatic voltage adjustment depending on the concentration of salt and
the temperature, keeping continuous chlorine production.
- Automatic cleaning cycle of electrodes.
- Automatic restart in the event of supply failure.
1.4- Recommendations and safety precautions
- The equipment should always be installed by qualified staff.
- Disconnect the equipment from the mains before performing any
assembly or maintenance operation.
- Make sure that the electrical installation has all compulsory
protection elements (circuit breaker and differential switch) in
perfect condition.
- It is important to ensure that the supply cables of the
electrolysis cell are tightly connected, otherwise the
equipment could overheat and break down.