EasyManua.ls Logo

BSV EVoBasic-35 - Warning Messages and Alarms (EVO); Warnings

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manual EVO v.3 86 / 142
"EXCESS SALT"
Excess salt in the water.
No action required if excess is
not very significant.
Incrustations or objects in
the electrolysis cell causing
excess current.
Clean the cell.
"CLEANING"
The chlorinator is in the
self-cleaning process. The
process lasts 5 minutes
None.
"TEMPERATURE".
The ambient temperature is
>40º
Try and place the equipment in
another position where it is not
over 40º or perform forced
ventilation. Leave the
equipment to rest for a few
minutes.
Consult section number
4. Installation
The radiator fins are
obstructed or are not in a
vertical position.
Place the equipment so that air
is circulated for correct cooling.
4.4.1.1- Additional warning messages
ORP or PPM value is
flashing
The redox or free
chlorine probe are
balanced in automatic
mode. When the probe
is balanced, the value
remains set.
None.
pH value is flashing
The pH probe is
balancing. When the
probe is balanced, the
value remains set.
None.
Value ---o (Water
temperature) is flashing
The value of the water
temperature is under
15º.
None.
Filter time
The equipment has
switched off before the
time set in semi-
automatic
Restart the filtering cycle