10- 40 Service Guide LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Electrical systems – 5000 LPE 240
Parameters
T-code Valid from serial number Date Order number
660, 661, 662, 497 723984- 2005-05-11 225553-040
Instructions for verifying parameter setting
Charge up the battery
Use the truck in its normal application until the battery indicator
shows an empty battery (0% on the display).
Disconnect the battery from the truck and allow the battery to rest for
at least two hours. NB! No charging or discharging during this peri
-
od.
Measure the battery voltage at room temperature. If the voltage is
less than U
end
, see the table below, the parameter value must be re-
duced. If the value significantly exceeds U
end
, the risk of damage to
the battery is reduced. At the same time, the operating time of the
truck is reduced. If a longer operating time is required, the parameter
value can be increased. Maximum one unit.
Each change must be accompanied by a new verification of the pa-
rameter setting.
Parameter 22
You must specify the type of brake switch the truck is equipped with.
Mechanical switch = 0
Inductive sensor= 1
Parameter 25
Using this parameter you can specify a limit for when the next service is
to take place, from 0 to 2000 hours, in 50-hour steps. When it is time for
a service, warning 29 (C29) is shown in the display.
Parameter 28
Using this parameter you can select which button is to be used for lift/
lower.
1 = Bottom lift/lower button activated (default)
2 = Top lift/lower button activated
3 = Both lift/lower buttons are activated
Battery type Battery voltage at rest, U
end
Hawker Evolution 24,24 V

Table of Contents