9-  34 Service Guide  LWE180, LWE200, LPE200, LPE240 © BT Europe AB
Electrical System – 5000 LWE 180/200 LPE 200
Parameters
T-code Valid from serial number Date Order number
660, 661, 662, 497  723984- 2005-05-11 225553-040
Parameter 18 - Configurable option #3
See “Option parameters” on page 34, Servicemanual
Parameter 19 - Configurable option #4
See “Option parameters” on page 34, Servicemanual
Option parameters
WARNING !
Do not try to change these parameter unless you have specific knowl-
edge of the truck options or truck modifications. This service manual 
only covers the truck’s standard equipment. Specially modified 
trucks may require you to have access to particular service informa
-
tion. Incorrect adjustment of option parameters may result in incor-
rect function.
General
Parameters #15 to #19 have been reserved in the truck control system 
for extra options and/or specific product modifications. These parame
-
ters are normally configured by the manufacturer on modification or 
customisation of the truck. It is recommended that the parameter set
-
tings be loaded up from the truck when carrying out any modification. If, 
for example, the main electronic card [A2] must be replaced, the origi
-
nal parameter settings can then be simply transferred to the new card, 
which ensures that all the special options function correctly.
Parameter #15 Non-configurable options
Up to 16 so-called sub-parameters are stored under parameter #15. 
Their status is either ON or OFF and they do not require any other 
adjustments. They are therefore called non-configurable options.
Changing non-configurable options
• Ensure the truck is in parameter mode.
The parameter symbol is lit.
• Select parameter #15 using [L1].
The first set-up of sub-parameters is displayed
The next set-up of sub-parameters is displayed if you continue to acti-
vate the speed control L1. Ensure that only the relevant sub-parame-
ters are displayed.
The value of the sub-parameters is displayed after 1 second.
• Press the horn button S18.