Electrical systems – 5000 LPE 240
Parameters
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497
© BT Europe AB Service Guide LWE180, LWE200, LPE200, LPE240 10- 27
10.6.3 Service parameters
Connect CAN-key in X41
Press S18 and turn S17 to on at the same time.
Press S18 until you read P= parameters.
You have now choosen P=parameters the symbol “C” on display will
be highlighted to indicate what’s currently shown on display.
Scroll to the parameter you want to change or look at by pressing the
L1 up or down.
Press S18 ones to get access to the parameter.
Set parameter value by pressing L1 up or down.
Press S18 ones to confirm change.
Turn S17 to off.
You have now completed a parameter change and the next time you
start the truck the new parameter setting will be valid.
NOTE !
Truck handling.
Modifying specific truck parameters will change the driving charac-
teristics of the truck.
Do not change any parameters without the necesarry know-how.
Parameter Description Unit Min
.
Max
.
Step Std
.
Description
10 PIN-code 0 9999 1 1
Facility for specifying up to 10
PIN codes (10 different drivers).
14 Crawling
speed
-10 10 1 0 The amount of power the mon-
itor should emit when you
reach the first speed sensor
can be specified here.
-10: low speed for the first
speed sensor.
10: high speed for the first
speed sensor
15 Non-config-
urable option
0 to 9
See “Option parameters” on page 29, Servicemanual
16 Configurable
option #1
See “Option parameters” on page 29, Servicemanual
17 Configurable
option #2
18 Configurable
option #3
19 Configurable
option #4
20 Hour meter
option
1 5 1 2 Select hour meter.