Electrical systems – 5000 LPE 240
Parameters
Order number Date Valid from serial number T-code
225553-040 2005-05-11 723984- 660, 661, 662, 497
© BT Europe AB Service Guide LWE180, LWE200, LPE200, LPE240 10- 39
Recommendation on parameter setting for
valve-controlled batteries (VRLA)
WARNING !
The service life of the battery will be reduced if the value of parameter
21 is set at too high a value. The standard setting of parameter 21 is
set for normal truck handling. Other applications may require a differ
-
ent setting of parameter 21. Check that the parameter setting is the
correct one using the instructions below.
Parameter 21 Battery size LPE200-8
Less discharge
Greater discharge
1
2
3
4
5 570Ah - 640Ah
6 510Ah - 560Ah
7 430Ah - 500Ah
8 370Ah - 420Ah
9 300Ah - 360Ah
10
11
12
13
14
15
16
17
18
19
20