SMART 200 TTS & IS3W/TTS
YARN CONTROL SYSTEM
Operating Manual
Rev. 2.0 – August 2003 ENGLISH

Table of Contents

Questions and Answers

  • C
    Colton MaciasAug 8, 2025
    Why is the SMART display blank on my BTSR Control Systems?
    • G
      Garrett LewisAug 8, 2025
      If the SMART display is blank, ensure the I/O connector is correctly plugged in and that there's a 24 Vdc power voltage on pins 1-2. Also, check the protection fuses, as the system may be powered off.
  • M
    millercoleAug 13, 2025
    What to do if the display shows the ERR COM DXXX screen on btsr SMART 200 TTS Control Systems?
    • L
      laurenjohnsonAug 13, 2025
      If the display shows the ERR COM DXXX screen on your BTSR Control Systems, the issue might be a faulty or incorrectly numbered sensor. Try assigning a number to the sensor XXX again. If the problem persists, replace the sensor or check the connection cable of the sensor and replace it if necessary. As a final step, try assigning a number to all the sensors again.
  • R
    Ryan SchwartzAug 17, 2025
    Why is the sensors numbering procedure failing on my btsr SMART 200 TTS?
    • S
      Samantha LopezAug 17, 2025
      If the sensors numbering procedure fails (the number YYY does not increase in the screen DEV *Y* XXX YYY), verify that the sensors are correctly connected. Also, check for locked sensors (green and red LED simultaneously ON) and power off and on the system. If the problem persists, replace the sensor or connect a set of sensors at a time trying to isolate the problem.
  • M
    msandovalAug 21, 2025
    What to do if SMART system does not accept keyboard inputs on BTSR Control Systems?
    • J
      Jennifer NashAug 21, 2025
      If the SMART system does not accept keyboard inputs, and the keyboard is not responding on your BTSR Control Systems, the system might have halted due to a sudden over-voltage load. Power off and then on the system. If the problem continues, contact your BTSR reseller.
  • C
    Cindy PerkinsAug 26, 2025
    What does the ERR_OUT DEV XX screen mean on btsr SMART 200 TTS?
    • N
      Nicole DownsAug 27, 2025
      If the display shows the ERR_OUT DEV XX screen on your BTSR Control Systems, the Stop output transistor STOP might be shortened. Check the STOP circuit. If the problem persists, replace the sensor.
  • D
    Diane GriffinAug 29, 2025
    How to fix a sensor that does not provide the Stop signal on btsr SMART 200 TTS?
    • M
      Mark DavisAug 29, 2025
      If the sensor does not provide the Stop signal on your BTSR Control Systems, there might be a failure in the Stop circuit. Check the Stop circuit connections and the configuration of the Stop signal (ST-NCO). If the problem persists, replace the sensor.
  • R
    Raymond GibsonSep 3, 2025
    What does ERROR RAM message at startup mean for BTSR Control Systems?
    • J
      Joseph KirkSep 3, 2025
      If you see an ERROR RAM message at startup on your BTSR Control Systems, press the button to erase user settings and load default values, then reload your parameters and custom settings. If the problem persists, contact your BTSR reseller. The replacement of the system’s lithium battery may be required.

btsr SMART 200 TTS Specifications

General IconGeneral
Power Supply24 VDC
Protection ClassIP20
Communication InterfaceRS485
Number of Axes1
Output Voltage24 VDC
CategoryControl System
Operating Temperature0°C to +50°C
Storage Temperature-20°C to +70°C
Output Current2 A