WARNING
Do not store a spare or disconnected liquid propane cylinder under or
near this single side burner.
A dented or rusty liquid propane cylinder may be hazardous and
should be check by your liquid propane provider.
Do not use a liquid propane cylinder with a damaged valve.
LIQUID PROPANE (LP) SAFETY OPERATING SPECS
Your Propane gas (G31) side burner is designed to operate on propane gas ONLY, at a pressure regulated
at 11” water column (wc.) or 27.4 mbar when equipped with the correct propane orifices on the valves and
a propane regulator on the supply line.
Your propane gas side burner is designed to be used with a standard 20 lb. gas cylinder. In the United
States, the LP gas cylinder must be constructed and marked in accordance with specifications of the US
Department of Transportation for Propane Gas Cylinders.
1) Always keep LP gas cylinder securely fastened in an upright position.
2) Never connect an unregulated LP gas cylinder to the grill.
3) Do not subject LP gas cylinders to excessive heat.
4) Do not fill LP gas cylinder beyond 80% full.
CAUTION: Never store LP gas cylinders inside a building or in the vicinity of any gas-burning appliance.
WARNING: When the outdoor cooking gas appliance is not in use:
1) The LP gas must be turned off at the supply cylinder. Storage of an outdoor cooking gas appliance indoors is
permissible only if the cylinder is disconnected and removed from the outdoor cooking gas appliance.
2) Spare LP gas cylinders must be stored outdoors, out of reach of children and must not be stored in a building,
garage or any other enclosed area.
3) The LP gas cylinder must be equipped with an arrangement for vapor withdrawal.
4) The LP gas cylinder must include a collar to protect the cylinder valve.
5) Do not store spare LP gas cylinders under or near this appliance. Place dust cap on cylinder valve outlet
whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is
provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.
SAFETY! BEWARE OF SPIDERS
CAUTION: BURNERS MUST BE INSPECTED AND CLEANED BEFORE FIRST USE.
Spiders and small insects occasionally spin webs or make nests in the burners during warehousing, transit and/or
after long periods of non- use. These webs can lead to a gas flow obstruction, which could result in a fire in and
around the burner tubes. This type of fire is known as “FLASH-BACK” and can cause serious damage to your grill
and create an unsafe operating condition for the user. Although an obstructed burner tube is not the only cause of
“FLASH BACK” it is the most common cause, and frequent inspection and cleaning of the burners is necessary.
WARNING: Gas valves are pre-set at the Bull factory to operate on LP Gas or Natural Gas. If you
wish to convert to a different gas type, other than LP or NG, be sure to contact your grill dealer,
licensed plumber or authorized service center for further details. Conversion kits are not sold to the
general public and require a professional to perform service. Failure to properly convert a unit can
cause serious injury to yourself and/or others, irreparable damage to your grill and void of warranty.
WARNING: IF THESE GUIDELINES ARE NOT FOLLOWED, FIRE CAUSING SERIOUS INJURY OR DEATH MAY OCCUR.