9
INSTALLATION INSTRUCTIONS (CONTINUED)
OUTDOOR PROPANE GAS SINGLE SIDE BURNER INSTALLATION SPECIFICATIONS
NOTE:
- Vents must be provided for combustion air and ventilation on both sides of built-in cabinet.
- When choosing a location for your single side burner keep in mind that it should never be located under any overhead
combustible construction.
- The sides and back of the single side burner should not be any closer than 21 inches/54 cm/533 mm to combustible construction.
- DO NOT store empty or full spare tanks under or near this or any other appliance.
- There must be a minimum of 6 inches/15 cm/152 mm counter space behind the single side burner in order to allow for ventilation
purposes.
- The cylinder valve on the tank must be readily accessible for hand operation. The tank must be isolated enough to where it is
shielded from radiation, open flames and protected from foreign matter such as hot drippings.
- There must be access so the tank can be connected, disconnected, inspected and leak tested outside of the cabinet. As well
access so that connections which could be disturbed when installing the tank in the cabinet can be leak tested inside the cabinet.