IMPORTANT: This step is performed on all vehicles.
PYROMETER CALIBRATION PROCEDURE
BEFORE THIS STEP CAN BE COMPLETED, COMPLETELY INSTALL THE OUTLOOK AND ALL OF ITS COMPONENTS.
1. Vehicle must be set to Stock HP/TQ levels-meaning no HP/TQ modifications of any kind (downloader or plug-in
modules).
2. Engine must be put under full load for as long as possible on the hottest day possible. It is suggested to drive up
a hill or pull a trailer.
3. During a heavy load pull, record the highest reading.
4. Take that reading and add 150° to the high number and that will be your new de-fuel number that you do not
want to exceed.