15
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
1. Use a more appropriate con-
centrate (between 4:1 to 11:1)
and adjust the product dial to
the proper Brix setting.
2. Remove nozzles and clean
with sanitizing solution to re-
move build-up. Follow Care
and Cleaning instructions and
run sanitizing solution through
system.
3. a) Remove nozzles and clean
with sanitizing solution to re-
move build-up. Follow Care
and Cleaning instructions and
run sanitizing solution through
system.
b) Water flow rate should be
factory pre-set to 133 ml (4.5
oz) per 3 second dispense.
To verify, switch to Program
mode. Place a graduated mea-
suring cylinder under the dis-
pense nozzle, pull and release
the tapper handle 3 times. The
dispenser will then dispense
an amount of water for 3 sec-
onds. If water flow rate is set
too low, adjust the water nee-
dle valve using a small flathead
screwdriver and turning the
needle counter-clockwise.
c) Clean the system by follow-
ing the Care and Cleaning in-
structions.
1. The product pump speed is set
too high (at max) to dispense
a lower ratio product (below
4:1).
2. The nozzle has accumulated
build-up or debris.
3. a) The nozzle has accumulated
build-up or debris
b) The water needle valve on
right-side of deck may be set
too low (only affects Still Dis-
pense station)
c) The system needs cleaning
Irregular Flow from Nozzle
1. Flow is pulsating/ hammering
2. Flow coming out at an angle
3. Flow rate is slow
55124 021418