16
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
Unit Performing Inconsistently
(Brix/Nitro fluctuating wildly or
outside normal range)
1. System was installed/set-up
incorrectly or has been placed
in an environment with unac-
ceptable conditions:
a. Incorrect water line size
b. Incorrect gas line size
c. Fluctuations in water or
gas supply pressures
d. Ambient temperature too
high or low
2. System has internal malfunc-
tion and needs service by a
technician
1. a) Install a water line that is
in accordance with machine
specifications.
b) Install a gas line that is in
accordance with machine
specifications.
c) Assure the unit is being fed
consistent and constant gas
and water pressure.
d) Place the unit in a location
in accordance with machine
specifications.
2. Call Customer Support for as-
sistance.
55124 021418