6 | Electrical Connection
22 | 52 Instruction Manual COBRA NC 2500 B WCV_EN_en
NOTICE
Incorrect direction of rotation.
Risk of damage to the machine!
Operation in the wrong direction of rotation can destroy the machine in a short time! Prior to
start-up, ensure that the machine is operated in the right direction.
The intended rotation direction of the motor is defined by the illustration below:
Jog the motor briefly.
Watch the fan wheel of the motor and determine the direction of rotation just before the fan
wheel stops.
If the rotation of the motor must be changed:
Switch any two of the motor phase wires.
6.3 Electrical Connection of the Cooling Liquid Pump
DANGER
Live wires.
Risk of electrical shock.
Electrical installation work must only be executed by qualified personnel.
Provide an overload protection according to EN 60204-1 for the pump.
Electrically connect the cooling liquid pump.
Make sure that the cooling liquid pump is connected such that is running when the machine is
started.