Commissioning | 7
Instruction Manual COBRA NC 2500 B WCV_EN_en 27 | 52
After a few minutes of operation, perform an Oil Level Inspection [30].
After a few minutes of operation, perform a Cooling Liquid Level Inspection [30].
As soon as the machine is operated under normal operating conditions:
Measure the motor current and record it as reference for future maintenance and trouble-
shooting work.
7.1 Recommendations on Operation
7.1.1 Operating Frequency
Operate the machine continuously at 35 ... 60 Hz (2100 ... 3600 min
-1
).
For continuous operation at 20 ... 35 Hz, for example for stand-by purposes, an acceleration ramp
of 12 minutes for 0 … 60 Hz must be used (acceleration of 5 Hz per minute) or the inlet pressure
must be kept at >100 mbar for cooling purposes. The G 1/2 connection at the machine inlet spool
piece can be used to inject ambient cooling air.
Operation below 20 Hz is not recommended.
Maximum allowed operation frequency is 60 Hz (3600 min
-1
).
7.1.2 Stop & Start
Frequent stop-start operation to be avoided.
Use acceleration ramp of 12 minutes for 0 … 60 Hz for start.
Or, for fast start (30 seconds for 0 … 60 Hz), wait >60 minutes between stop and start.
7.1.3 Use with Argon
Pumping of high Argon concentrations (up to 50-80% of Argon) requires additional limits of opera-
tion:
Rotational speed: max 50 Hz = 3000 min
-1
.
Gas inlet temperature: max. 80 °C.
Cooling gas: air or nitrogen.
Temperature monitoring: standard setting.
7.2 Conveying Condensable Vapors
The machine is suitable for the conveyance of condensable vapors within the gas flow.
If condensable vapors are to be conveyed:
START
Start the machine to warm it up
Wait 30 minutes
Open the inlet valve
Perform the process
Close the inlet valve
END
Continuously drain condensate from the condensate drain plug (CD) of the silencer (SI) (Optional).