Electrical Connection | 6
Instruction Manual_MINK MV 1202 B_EN_en 13 | 32
6 Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
● Electrical installation work must only be executed by qualified personnel.
DANGER
Missing current protection.
Risk of electrical shock.
● Current protection in accordance with EN 60204-1 must be provided by the customers on their in-
stallation(s).
● The electrical installation must comply with the applicable national and international standards.
● Install a semiconductor temperature detector to the release device in accordance with the wiring
diagram.
NOTICE
Electromagnetic compatibility.
● Make sure that the motor of the machine will not be affected by electric or electromagnetic dis-
turbance from the mains, if necessary seek advice from Busch.
● Make sure that the EMC of the machine is compliant with the requirements of your supply net-
work system, if necessary provide further interference suppression (EMC of the machine, see EU
Declaration of Conformity [➔28] or UK Declaration of Conformity [➔29]).
6.1 Machine delivered without Control Box or
Variable Speed Drive (VSD)
DANGER
Live wires.
Risk of electrical shock.
● Electrical installation work must only be executed by qualified personnel.
● Make sure that the power supply for the motor is compatible with the data on the nameplate of
the motor.
● If the machine is equipped with a power connector, install a residual current protective device to
protect persons in case of a defective insulation.
● Busch recommends installing a type B residual protective device suitable for the electrical in-
stallation.
● Provide a lockable disconnect switch or an emergency stop switch on the power line so that the
machine is completely secured in case of an emergency situation.