Product Description | 2
Instruction Manual_MINK MV 1202 B_EN_en 5 | 32
2.1 Operating Principle
The machine works on the claw principle.
The MINK is fully air-cooled thanks to an integrated fan in the drive unit.
In order to avoid solids from entering, the machine is equipped with an inlet screen (IS).
2.2 Intended Use
WARNING
In case of foreseeable misuse outside the intended use of the machine.
Risk of injuries!
Risk of damage to the machine!
Risk of damage to the environment!
● Make sure to follow all instructions described in this manual.
The machine is intended for the suction of air and other dry, non-aggressive, non-toxic and non-ex-
plosive gases.
Conveying of other media leads to an increased thermal and/or mechanical load on the machine
and is permissible only after a consultation with Busch.
The machine is intended for the placement in a non-potentially explosive environment.
The machine is designed for indoor installations. For outdoor installations, consult your Busch repre-
sentative for special precautions.
The machine is not capable of maintaining ultimate pressure.
● The minimum allowed ultimate pressure is to be read from the nameplate of the machine.
● By means of process control and/or vacuum relief valves it must be made sure that the mini-
mum allowed ultimate pressure will not be underrun.
In order to avoid reverse rotation after switching off, the machine can be equipped with an optional
non-return valve (NRV).
Note: The non-return valve (NRV) is no reliable means to prevent suction and shall not be used as a
non-return valve or shut-off valve for the system.
If the machine needs to be maintained after shutdown:
● Provide an additional manual or automatic operated non-return valve in the suction line.
Permitted environmental conditions, see Technical Data [➔26].