Problem Possible Cause Remedy
The machine does not reach
the usual pressure on the suc-
tion connection.
The inlet screen (IS) is partially
clogged.
Clean the inlet screen (IS).
The vacuum relief valve (VRE) is
misadjusted or defective.
Replace the vacuum relief
valve (VRE)
The inlet filter cartridge (op-
tional) is partially clogged.
Replace the inlet filter car-
tridge.
Internal parts are worn or
damaged.
Repair the machine (contact
Busch).
The machine runs very noisily. Worn coupling (CPL). Replace the coupling (CPL).
Oil level too low. Top up oil.
Defective bearings. Repair the machine (contact
Busch).
The machine runs too hot. Insufficient cooling. Remove dust and dirt from
the machine .
The cooling fan’s rotation di-
rection is incorrect.
Check the rotation direction
of the cooling fan, if needed
switch any one of the two
power supply wires.
Ambient temperature too high. Observe the permitted am-
bient temperature, see Tech-
nical Data [26].
Temperature of the process
gases at the inlet too high.
Observe the permitted gas
inlet temperature, see Tech-
nical Data [26].
Oil level too low. Top up oil.
For resolution of problems not listed in the troubleshooting table, please contact your Busch repre-
sentative.