5 Installation
5.1 Installation Conditions
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
Take care that the installation conditions are fully complied with.
Make sure that the environment of the machine is not potentially explosive.
Make sure that the ambient conditions comply with the Technical Data [36].
Make sure that the environmental conditions comply with the protection class of the motor and
the electrical elements.
Make sure that the installation space or location is protected from weather and lightning.
Make sure that the installation space or location is vented such that sufficient cooling of the ma-
chine is provided.
Make sure that cooling air inlets and outlets are not covered or obstructed and that the cooling
air flow is not affected adversely in any other way.
Check the oil level, see Oil Level Inspection [25].
Make sure that all provided covers, guards, hoods, etc. are mounted.
Make sure that the machine is secured against movement.
5.2 Blower Unit Installation
The machine must be set up horizontally on a flat surface.
Maximum permissible unevenness of the base / inclination of the machine can be expressed as fol-
lows:
View from left to right and the front to back : max. 0.5°
We recommend to keep 1 meter space around the machine for the maintenance work.