Maintenance | 8
Instruction Manual TYR WT 0100-0730 CP CV_EN_en 23 | 44
or
Close the cover after that
Clean or Change the Inlet Filter
8.3 Maintenance Belt and Pulley Alignment
Interval Maintenance work
After 10-20 operating hours ● Check the belt tension.
● Check the pulley alignments.
Half – yearly (or more often de-
pending on application).
● Check the belt tension.
● Check the pulley alignments.
Once a year ● Change the belts.
● Belt change intervals for higher loads and ambient tem-
peratures (more than +40°C) range from 4000 to max. 8000
hours.